DS810 | DS820 | |||
---|---|---|---|---|
Measurement range | Clearance distance | 25 mm | 63 mm | |
Z-axis (height) | Measurement range | 5 mm | 16 mm | |
X-axis (width) | Near field of view | 10.5 mm | 22 mm | |
Middle field of view | 11 mm | 25 mm | ||
Far field of view | 11.5 mm | 28 mm | ||
Laser (light source) | Wavelength | 450 nm (blue) | ||
Laser class | 3R | |||
Output power | 2x Outputs, 24 VDC (max. 20 mA) | |||
Spot size (middle field of view) | 5.8–6.8 μm | 11.5–14.5 μm | ||
Sensor | Data points/profile | 1920 | ||
X resolution | Top | 5.8 µm | 11.5 µm | |
Bottom | 6.8 µm | 14.5 µm | ||
Z resolution | Top | 0.37 µm | 1.1 µm | |
Bottom | 0.45 µm | 1.6 µm | ||
Z repeatability1 | Top | 0.1 µm | 0.2 µm | |
Bottom | 0.1 µm | 0.2 µm | ||
Z linearity2 | 0.015% | 0.005% | ||
Temperature characteristics |
Operating Temp: 0–40 °C (32–104 °F) Storage Temp: -20–70 °C (-4–158 °F) |
|||
Environmental resistance | Housing protection | IP65 | ||
Operation temperature3 | 0–40 °C (32–104 °F) | |||
Storage temperature | -20–70 °C (-4–158 °F) | |||
Maximum humidity | 20–90%, non-condensing | |||
Scan rate | up to 10 kHz | |||
Housing material | Aluminum | |||
Weight | < 550g | |||
Dimensions | 45 mm x 74 mm x 111 mm | |||
Power supply requirements | 24 VDC | 0 V | |||
Inputs | 2x inputs (5 - 24VDC) | Quadrature Encoder (AB - Channel, RS-422 standard) | |||
Trigger | START on input 1-2 | DATA on Quadrature Encoder input | DATA Trigger on input 2 | |||
Encoder specifications | RS-422 standard | |||
Interface | Gigabit Ethernet |
1 Z repeatability is measured an average of 100 times over a pointcloud using a 4x4 mm area, at the middle of the measurement range.
2 Z linearity is the maximum deviation of 250 position measurements on the measurement range, where a measurement is the average of 2 profiles using the standard Cognex target.
3 Mounted to a 400 mm aluminum bar on top of the camera.