Technologies 3D Symbolic Light
Acquisition Rate Up to 3 Hz (acquisition and on-board processing)
Trigger Trigger input voltage limits: 24 VDC
Input ON: >10 VDC (>6 mA)
Input OFF: <2 VDC (<1.5 mA)
Power Voltage: +24 VDC (22–26 VDC)
Current: 1A rms, 3A max; 5A max with HPIA
2D Vision 1280 x 960 resolution
Modular external lighting & filter
Communication GigE, TCP/IP, PROFINET, EtherNet/IP(TM), M/S
I/O 2 fixed inputs, 2 fixed outputs
Operating Temperature 0–40 °C (32–104 °F)
Storage Temperature -10–60 °C (14–140 °F)
Operating Humidity < 85% (non-condensing)
Weight 485 g (17.1 oz)
Protection IP65
Certifications CE, FCC, KCC, TUV SUD NRTL, RoHS

Working Distance (mm) Carrier (mm) Max Speed (m/s)
<900 600 x 400 <1.5
<1200 900 x 600 <2.1
<1500 1200 x 900 <2.5
<1800 1500 x 1200 <2.5

Minimum Detectable Objects vs Working Distance

*Additional advanced inspection features can allow the detection of high contrast objects that are below the minimum height specification with reduced outputs

3D-A1000 working distance specifications
FEATURED COGNEX PRODUCTS

GET ACCESS TO SUPPORT & TRAINING FOR PRODUCTS & MORE

Join MyCognex