DataMan 474 | DataMan 475 | |
---|---|---|
Algorithms and Technologies | 1DMax, 2DMax, Hotbars, PowerGrid | |
Image Sensor | 1/1.8″ CMOS | 2/3″ CMOS |
Image Sensor Properties | Diagonal 8.9 mm; 3.45 µm square pixels | Diagonal 11.1 mm; 3.45 µm square pixels |
Image Sensor Resolution | 2048 x 1536 | 2448 x 2048 |
Electronic Shutter Speed |
Min. exposure: 15 µs Max. exposure: 1000 µs with internal illumination/10000 µs with external illumination |
|
Max Acquisition | Up to 80 Hz | Up to 55 Hz |
Lens Options | Liquid lens 8 mm, 10 mm, 16 mm, 24 mm, 35 mm; C-mount 12 mm, 16 mm, 25 mm, 35 mm, 40 mm | |
Trigger and Tune Buttons | Yes; Quick Setup Intelligent Tuning | |
Aimer | Optional | |
Discrete Inputs | 2 fixed + (*) opto-isolated | |
Discrete Outputs | 2 fixed + (*) opto-isolated | |
*Other I/O Points | 2 user-configurable | |
Status Outputs | Beeper, 5 multifunctional LEDs, 10 LED bar array, 360 degree indicator | |
Lighting | Integrated LEDs, red, blue, or IR; diffuse, polarized, high powered integrated light (HPIL), high powered integrated torch (HPIT), various controllable external light options | Integrated LEDs, red, blue or IR; diffuse, polarized, high powered integrated torch (HPIT), various controllable external light options |
Communications | Ethernet and Serial | |
Protocols |
RS-232, TCP/IP, PROFINET, EtherNet/IP(TM), SLMP, Modbus TCP, NTP, SFTP, FTP, MRS Java Scripting enabled for custom protocols |
|
Power | 24 VDC ±10% | |
Power Consumption |
24 VDC ±10%, 1.5 A maximum (HPIL/HPIT1) 24 VDC, 250 mA maximum (reader) Supplied by LPS or NEC class 2 only |
|
Weight | 373 g | |
Dimensions | 126.8 mm (L) x 60.5 mm (W) x 77.1 mm (H) | |
Operating Temperature | 0–57 °C (32–134.6 °F)2 | |
Storage Temperature | -20–80 °C (-4–176 °F) | |
Operating and Storage Humidity | < 95% non-condensing | |
Protection | IP67 with cables and appropriate lens cover attached | |
RoHS Certified | Yes | |
Approvals (CE, UL, FCC) | Yes |
1 HPIL denotes one of the DM360-HPIL-RE, DM360-HPIL-RE-P, DMLT-HPIL-RE or DMLT-HPIL-RE-P accessories. HPIT denotes one of the DMLT-HPIT-RE-W, DMLT-HPIT-RE-S, DMLT-HPIT-RE-N, DMLT-HPIT-WHI-W, DMLT-HPIT-WHI-S, DMLT-HPIT-WHI-N accessories.
2 In situations where the operating temperature exceeds 40 °C, an external heat sink is required.